Back

Driver Repair Services

Professional repair for NSK, Panasonic, Yokogawa, Yaskawa drivers
OEM-grade quality with fast response

NSK Panasonic Yokogawa Yaskawa

Service Advantages

Expert diagnosis, OEM-grade repair, complete testing

Expert Diagnosis

Complete technical documentation and experienced engineers for quick problem identification

OEM-Grade Repair

Using matching components and specifications, repair quality equals OEM standards

High-Load Testing

All repairs undergo actual simulation testing to ensure normal operation before shipping

Multi-Brand Compatible

Support for various brands and models with customized repair solutions

NSK Driver Repair

ESA / EDC / ELC Series
ESA-Y2020A23-11
ESA-Y2020T25-21
ESA-Y3040A23-21
ESA-Y3040T23-11
ESA-Y4080T23
ESA-Y5120T23
ESA-Y5240T23
ESA-Y2020V23
ESA-Y3040V23
ESA-LYA1A13
ESA-LYA1A13-21
ESA-LYA2AFH-20
ESA-J1003AFD-20
ESA-J1003A25-21
ESA-0408A35-21.1
ESA-B045AF3-21
EDC-PS1006AB502
EDC-PS1012CB5F5
EDC-PS3015AB501
EDC-PS3060AB5F5
EDC-PS3090AB501
EDC-PS3090AB502-A
ELC-JG014VF1-01
ELC-JG014VF1-02
ELC-JG014VF1-03
ELC-JG014VF2-01
Issue TypeCommon Symptoms
Power FailureCannot start, fuse blown
Communication ErrorRS-232 no response, controller disconnected
Drive AbnormalityMotor cannot drive, alarm triggered, overload error
Connector/Capacitor DamageSolder joint loose, component aging, leakage

Panasonic Driver Repair

MINAS A6 / A5 / A4 / A Series
MSDA3A3A1A
MSDA5A3A1A
MSDA013A1A
MSDA023A1A
MSDA043A1A
MSDA083A1A
MSDA103A1A
MSDA153A1A
MSDA203A1A
MSDA253A1A
MSDA303A1A
MSDA353A1A
MSDA403A1A
MSDA453A1A
MSDA503A1A
MADDT1205003
MADDT1207003
MADDT1207052
MADDT1207053
MBDDT2210003
MCDDT3520003
MCDDT3520052
MCDDT3520053
MDDDT3530003
MDDDT5540003
MEDDT7364
MFDDTA390
MBDHT2510
MBDHT2510CA1
MBDHT2510E
MCDHT3520
MCDHT3520CA1
MCDHT3520E
MDDHT5540
MEDHT7364
MADLT05SF
MADLT15SF
MBDLT25SF
MCDLT35SF
MDDLT55SF
MDDLT64SF
MEDLT83SF
MFDLTA3SF
DV467TB
MSD021A1XX04
MSD043A1Y03
MSD023P1E
MSD303A1W
MSDB083D1D06
MSD3AZA1Y03

These drivers are typically paired with MSMA series servo motors, widely used in semiconductor processes, automation equipment, machine tools, and optoelectronic production lines.

Issue TypeCommon SymptomsRecommended Action
Power Not StartingNo display, fan not runningCheck AC input voltage, test fuse and power module
AL.11 AlarmMotor overheatingCheck if load exceeds limit, verify motor temperature
AL.13 AlarmEncoder abnormalityReconnect connector, replace encoder or test cable
AL.15 AlarmMotor overcurrentCheck drive parameters and motor wiring
AL.16 AlarmOvervoltage protectionCheck braking resistor, add regenerative resistor
Communication FailureCannot connect to PLC/controllerCheck baud rate, transmission format, address settings
Motor Vibration/NoiseUnstable motor, shakingAdjust servo gain parameters, check structure
ERR Display/Flashing LEDLED flashing, no responseTry reset, if persistent send for repair

Yokogawa Driver Repair

UR / UD / TM Series
UR1015C6BB-2XN
UR1015C6BB-2XN/D030232
UR1015C8DB
UR1015C6CB-2SN
UR1015B5BA
UD31001045-2SN
TM21001045-2SN
UR1EG3-250Z-1KD-2SA-N
UR1AG3
UR1BG3
UR1CG3
UR1FG3

Most Yokogawa Dynaserv drivers have no code display screen; diagnosis relies on LED status lights and external behavior. We recommend using OEM test motors and simulators to verify main circuit functionality.

Status Code / SymptomProblem DescriptionRecommended Action
POWER not litMain power not input, internal power abnormalityCheck AC input, fuse or rectifier module
ERR light on/flashingControl error, internal failure, EEPROM errorRestart, if persistent send for repair
Motor cannot driveOutput drive signal abnormality, main circuit damageTest IGBT, check motor connection
Communication failureRS-232 or other communication module failureVerify settings, check cable and interface
Position offset / poor repeatabilityEncoder (Resolver) abnormality, mechanical loosenessTest feedback system, check installation and wiring
Motor vibration / abnormal heatingControl parameter error or motor short circuitCheck gain settings, rewire or replace motor
Alarm on startupInitial value error, feedback out of sync, interferenceReset alarm, use test platform for simulation check
Motor won't rotate, no alarmOutput power module burned or output short circuitMeasure phase voltages, check IGBT or main board

Yaskawa Driver Repair

Sigma-7 / Sigma-5 / Sigma-II / Sigma-III Series
SGD7S-R70A00A
SGD7S-R90A00A
SGD7S-1R6A00A
SGD7S-2R8A00A
SGD7S-5R5A00A
SGD7S-7R6A00A
SGD7S-120A00A
SGD7S-180A00A
SGD7S-200A00A
SGD7S-330A00A
SGD7S-470A00A
SGD7S-550A00A
SGDV-R70A01A
SGDV-R90A01A
SGDV-1R6A01A
SGDV-2R8A01A
SGDV-5R5A01A
SGDV-7R6A01A
SGDV-120A01A
SGDV-180A01A
SGDV-200A01A
SGDV-330A01A
SGDV-470A01A
SGDV-550A01A
SGDH-01AE
SGDH-02AE
SGDH-04AE
SGDH-08AE
SGDH-10AE
SGDH-15AE
SGDH-20AE
SGDH-30AE
SGDH-50AE
SGDH-75AE
SGDH-01BEY222
SGDS-01A01A
SGDS-02A01A
SGDS-04A01A
SGDS-08A01A
SGDS-10A01A
SGDS-15A01A
SGDS-20A01A
SGDS-30A01A
SGDM-1AADA
SGDA-02APP
SGDA-02VS
SGDA-08APPY70
CACR-SR60BE12D-CY119
CACR-01-DS3BUC
CLSR-1B-N2CB
CPCR-0101-NQ1C
PMC-U-MP23AS1C011
XD-08-MN0A
JUSP-NS310
Alarm CodeProblem NameRecommended Action
AL.13Motor overheatingReduce load, check motor fan and ventilation
AL.14Driver overheatingClean heatsink, check fan operation
AL.15OvercurrentReduce load, check motor wiring and grounding
AL.16OvervoltageInstall regenerative resistor, adjust deceleration curve
AL.20Encoder abnormalityCheck encoder wire, reconnect or replace encoder
AL.30Parameter setting errorReset parameters or rewrite settings
AL.40Communication failure (e.g., EtherCAT)Check communication line, IP configuration, master connection
AL.72Software limit errorCheck settings, adjust command output
AL.84Parameter change abnormalityRestart and retry, initialize settings if necessary

Need Repair Services?